[1]李俊,*,冀科峰,等.预制装配式外墙用纤维增强杆拉伸试验研究[J].山东建筑大学学报,2019,(1):15-19.[doi:10.12077/sdjz.2019.01.003]
 LI Jun,*,JI Kefeng,et al.Tensile test of fiber reinforced bar for prefabricated external wall[J].Journal of Shandong jianzhu university,2019,(1):15-19.[doi:10.12077/sdjz.2019.01.003]
点击复制

预制装配式外墙用纤维增强杆拉伸试验研究()
分享到:

《山东建筑大学学报》[ISSN:1673-7644/CN:37-1449/TU]

卷:
期数:
2019年1期
页码:
15-19
栏目:
研究论文
出版日期:
2019-01-25

文章信息/Info

Title:
Tensile test of fiber reinforced bar for prefabricated external wall
文章编号:
1673-7644(2019)01-0015-05
作者:
李俊1*冀科峰2公超3聂成才1
(1.山东省建筑科学研究院,山东 济南 250031;2.济南中建建筑设计院有限公司,山东 济南 250101;3.山东省建设建工(集团)有限责任公司,山东 济南 250014)
Author(s):
LI Jun1* JI Kefeng2 GONG Chao3et al.
(1. Shandong Provincial Academy of Building Research, Jinan 250031, China; 2. Jinan Zhongjian Architectural Design Institute Co., Ltd., Jinan 250101, China; 3. Shandong Construction Group Co., Ltd., Jinan 250014, China)
关键词:
预制装配式外墙纤维增强杆环氧树脂砂浆拉伸试验
Keywords:
prefabricated external wall fiber reinforced bar epoxy mortar tensile test
分类号:
TU55
DOI:
10.12077/sdjz.2019.01.003
文献标志码:
A
摘要:
拉伸试验是研究预制装配式外墙用纤维增强杆拉伸性能的基本方法,对纤维增强杆现有的拉伸性能试验方法进行改进,可以解决拉伸试验易出现的数据偏低或偏高、离散性大等问题,为装配式建筑工程的设计和验收提供理论依据。文章针对纤维增强杆的特性及拉伸试验时出现的问题,对拉伸实验的试件制作方法、试件初始横截面积的测定、试验夹具设计等进行改进,并对3组15个试件的拉伸试验试验结果进行分析。结果表明:采用钢套管和环氧树脂砂浆对杆件的夹具夹持端进行灌浆锚固制作拉伸试件,用设有横向肋纹的直角三角槽夹具装夹并进行拉伸,试件均为有效破坏,试验成功率为100%;采用排水法测定杆件的初始横截面积,设置拉伸速度自动提示切换的试验方案,拉伸强度和拉伸弹性模量最大相对误差均<±20%,变异系数均<0.1,其数据的离散性小。
Abstract:
Tensile test is a basic method to study the tensile properties of prefabricated exterior wall fiber reinforced rods. By improving the existing test methods of tensile properties of fiber reinforced rods, the problems such as low or high data and large discreteness can be solved. It can provide theoretical basis for the design and acceptance of prefabricated building projects. This research improves the method of specimen making, the measurement of initial cross-sectional area of specimen and the design of test fixture. The results are analyzed based on the tension test of three groups of 15 specimens. The results show that steel sleeve and epoxy resin mortar are used to grout and anchor the clamping end of the rod fixture to make tensile specimens. The clamping end is clamped and stretched with the right triangular groove fixture with transverse ribs. The specimens are effectively damaged and the success rate of the test is 100%. The initial cross-sectional area of the rod is measured by drainage method, and the test scheme of automatic prompting and switching of the stretching speed is set up. The maximum relative error of strength and tensile modulus of elasticity is less than±20%, and the coefficient of variation is less than 0.1. The discreteness of the test data is smaller.

参考文献/References:

[1]高丹盈,朱海堂,谢晶晶.纤维增强塑料筋锚杆及其应用[J].岩石力学与工程学报,2004,23(13):2205-2210. [2]杜钦庆.GFRP筋力学性能实验研究[D].南京:河海大学,2008. [3]唐协.玻璃纤维(GFRP)筋混凝土构件正截面承载力设计方法研究[D].成都:西南交通大学,2007. [4]陈仙娥.环氧树脂砂浆钢筋锚固法的应用[J].华东公路,2004(Z1):70-71. [5]GB/T 1447—2005,纤维增强材料拉伸性能试验方法[S].北京:中国标准出版社,2005. [6]GB/T 13096—2008,拉挤玻璃纤维增强塑料杆力学性能试验方法[S].北京:中国标准出版社,2008. [7]黎伟捷,李彪,杨勇新,等.我国FRP筋产品标准及指标的探讨[J].玻璃钢/复合材料,2014(8):101-104. [8]周继凯,杜钦庆,陈礼和,等.GFRP筋拉伸力学性能尺寸效应试验研究[J].河海大学学报(自然科学版),2008,36(2):242-247. [9]刘汉东,于新政,李国维.GFRP锚杆拉伸力学性能试验研究[J].岩石力学与工程学报,2005,24(20):121-125. [10]杨振茂,马念杰,孔恒,等.玻璃钢锚杆的试验研究[J].煤炭科学技术,2002,30(2):42-45. [11]田华,伊西特,李盼,等.一种改进的玻璃纤维锚杆拉伸试验模型[J].理化检验:物理分册,2015,51(2):109-112. [12]JG/T 406—2013,土木工程用玻璃纤维筋[S].北京:中国标准出版社,2016. [13]孙翠兰.高强度环氧树脂砂浆的制备与性能研究[J].中国胶粘剂,2017,26(3):40-43, 50. [14]张晓华,朱华,陈晓龙.环氧砂浆性能影响的研究[J].新型建筑材料,2016(5):23-25, 29. [15]满兴博,李钢锋,李永金,等.玻璃纤维复合材料拉伸试验及强度预测模型[J].电力建设,2013,34(12):97-101. [16]ACI 440.3R-04,Guide test methods for fiber-reinforced polymers (FRPs) for reinforcing or strengthening concrete structures[S].Michigan: American Concrete Institute,2004. [17]GB/T 228.1—2010,金属材料 拉伸试验 第1部分:室温试验方法[S].北京:中国标准出版社,2010.