[1]傅传国,刘玮,孔唯一,等.基于升降温全曲线的钢筋混凝土梁温度场分析[J].山东建筑大学学报,2015,(4):307-317.
 Fu Chuanguo,Liu Wei,Kong Weiyi,et al.The temperature field analysis of reinforced concrete beam based on heating and cooling whole curve[J].Journal of Shandong jianzhu university,2015,(4):307-317.
点击复制

基于升降温全曲线的钢筋混凝土梁温度场分析
()
分享到:

《山东建筑大学学报》[ISSN:1673-7644/CN:37-1449/TU]

卷:
期数:
2015年4期
页码:
307-317
栏目:
研究论文
出版日期:
2015-07-20

文章信息/Info

Title:
The temperature field analysis of reinforced concrete beam based on heating and cooling whole curve
作者:
傅传国刘玮孔唯一王玉镯
山东建筑大学土木工程学院,山东 济南250101
Author(s):
Fu Chuanguo Liu Wei Kong Weiyi et al.
School of Civil Engineering, Shandong Jianzhu University, Jinan 250101, China
关键词:
钢筋混凝土梁火灾温度场分析
Keywords:
reinforced concrete beam fire temperature field analysis
分类号:
TU37
文献标志码:
A
摘要:
文章基于ISO834标准升降温全曲线,运用ABAQUS非线性有限元分析软件,以钢筋混凝土矩形截面梁为例,进行了单面、三面及四面受火工况下的梁截面温度场分析,得出了梁截面不同观测点的温度随标准升降温全曲线的变化规律。结果表明:由于混凝土的热惰性,越靠近受火面温度变化梯度越显著,除直接受火的截面边界之外,截面内部的升温出现不同程度的滞后现象,离受火面距离越远,滞后时间越长;钢筋混凝土梁经历升降温全过程后,梁截面各点经历的升温峰值温度不同,达到升温温度峰值的时间也不同,越远离受火面越滞后;在受火面停止升温进入降温阶段时,截面内部可能还处在升温阶段,形成了钢筋混凝土梁在受火面升温时其外部受火面温度高于截面内部温度,而在受火面停止升温进入降温段时,截面内部温度存在高于外部温度的情况,此现象在分析受火灾作用钢筋混凝土梁的承载性能时应加以考虑。
Abstract:
The paper studies the change rule of temperature field of reinforced concrete structures in the process of rise and cooling temperature under high temperature which is of great significance to understand its when subjected to fire resistance. In this paper, based on standard ISO834 Heating and cooling curve, using the nonlinear finite element analysis software ABAQUS, with reinforced concrete rectangular section beam as an example, the beam cross section temperature field analysis on single side, three sides and four sides fire conditions has been carried out, and the whole temperature to time curve of the different observation points in beam section is obtained. The analysis results show that due to the thermal inertia of concrete, more close to the fire side of beam section, the temperature gradient is more significant. In addition to direct fire section boundary, the cross section of internal temperature appears different degree of hysteresis, the farther from the fire surface distance, the longer the time lag. After Heating and cooling process, in the beam section, the peak temperature of warming experience are different at various observation points and the time to reach the peak temperature are different too, and the more far away from the fire surface, the more lagging. When beam surface stopping heating and into the cooling stage, Cross section internal observation point may still in the phase of heating, so when beam external surface warming the internal temperature of thesurface is higher than the external surface, and when beam surface stopping heating and into the cooling stage, the temperature of the internal cross section are higher than that of beam surface.

相似文献/References:

[1]刘涛,桂钰,王兆清.FRP抗弯加固方法的研究进展[J].山东建筑大学学报,2009,(04):356.
 LIU Tao,GUI Yu,WANG Zhao-qing.Development review on flexural strengthening by FRP[J].Journal of Shandong jianzhu university,2009,(4):356.
[2]傅传国,王广勇,宫梅.钢筋混凝土框架节点火灾反应非线性分析[J].山东建筑大学学报,2009,(06):495.
 FU Chuan-guo,WANG Guang-yong,GONG Mei.Nonlinear analysis of reinforced concrete frame joints subjected to fire[J].Journal of Shandong jianzhu university,2009,(4):495.
[3]刘维瑞,张爱社,高翠兰,等.CFRP加固钢筋混凝土梁受弯承载力分析[J].山东建筑大学学报,2010,(03):327.
 LIU Wei-rui,ZHANG Ai-she,GAO Cui-lan,et al.Numerical analysis of RC beam flexural capacity strengthened with CFRP[J].Journal of Shandong jianzhu university,2010,(4):327.
[4]李志华,苏小卒.500MPa钢筋大保护层混凝土梁的裂缝性能[J].山东建筑大学学报,2010,(04):368.
 LI Zhi-hua,SU Xiao-zu.Research on cracking behavior of thick-cover concrete beams reinforced with 500MPa steel bars[J].Journal of Shandong jianzhu university,2010,(4):368.
[5]傅传国,于德帅,傅煜晨,等.预应力型钢混凝土梁火灾下抗弯承载力计算[J].山东建筑大学学报,2013,(03):189.
[6]李树明,陈海强,惠守江,等.火灾后无机胶植筋拉拔试验研究[J].山东建筑大学学报,2015,(5):429.
 LI Shuming,CHEN Haiqiang,HUI Shoujiang,et al.Experimental study on the inorganic anchorage drawing after fire[J].Journal of Shandong jianzhu university,2015,(4):429.
[7]傅传国,孔维一,王玉镯.火灾下钢筋混凝土托梁转换结构承载性能分析[J].山东建筑大学学报,2015,(6):511.
 Fu Chuanguo,Kong Weiyi,Wang Yuzhuo.Bearing performance analysis of reinforced concrete structure with bearing column girder transfer floor under fire and coupling with vertical loads[J].Journal of Shandong jianzhu university,2015,(4):511.
[8]王玉镯,王灿灿,傅传国.火灾中带裂缝钢筋混凝土梁承载力算法研究[J].山东建筑大学学报,2016,(01):7.
 WANG Yuzhuo,WANG Cancan,FU Chuanguo.Calculation method of bearing capacity of reinforced concrete beam with cracks under fire[J].Journal of Shandong jianzhu university,2016,(4):7.
[9]傅传国,*,宋亚敏,等.热力耦合作用下钢筋混凝土梁抗剪性能试验研究[J].山东建筑大学学报,2018,(05):1.[doi:10.12077/sdjz.2018.05.001]
 Fu Chuanguo,*,Song Yamin,et al.Experimental study on shear bearing capacity of reinforced concrete beams under thermodynamic coupling[J].Journal of Shandong jianzhu university,2018,(4):1.[doi:10.12077/sdjz.2018.05.001]

更新日期/Last Update: 2015-07-25