[1]刁乃仁 张耀中 高承苗 石维群 崔萍.地埋管地源热泵系统余冷利用分析[J].山东建筑大学学报,2012,(02):133-136.
 DIAO Nai-ren,ZHANG Yao-zhong,GAO Cheng-miao,et al.Study on the cold storage application based on the ground-coupled heat pump system[J].Journal of Shandong jianzhu university,2012,(02):133-136.
点击复制

地埋管地源热泵系统余冷利用分析()
分享到:

《山东建筑大学学报》[ISSN:1673-7644/CN:37-1449/TU]

卷:
期数:
2012年02期
页码:
133-136
栏目:
研究论文
出版日期:
2012-04-30

文章信息/Info

Title:
Study on the cold storage application based on the ground-coupled heat pump system
作者:
刁乃仁 12 张耀中3 高承苗3 石维群3 崔萍3
1.山东建筑大学 可再生能源建筑利用技术省部共建教育部重点实验室,山东 济南 250101;2.山东建筑大学 山东省建筑节能技术重点实验室,山东 济南 250101;3.山东建筑大学 热能工程学院,山东 济南 250101
Author(s):
DIAO Nai-ren12 ZHANG Yao-zhong3 GAO Cheng-miao3 et al.
1. Key Laboratory of Renewable Energy Utilization Technology in Building of National Education Ministry, Shandong Jianzhu University, Jinan 250101, China; 2. Shandong Provincial Key Laboratory of Building Energy-Saving Technology, Shandong Jianzhu University, Jinan 250101, China; 3. School of Thermal Energy Engineering, Shandong Jianzhu University, Jinan 250101, China
关键词:
为了基于地板辐射供冷利用地埋管地源热泵系统余冷提供初步的计算依据建立了地板辐射供冷传热模型通过数值求解给出了理论计算结果分析了供水温度、室内设计温度、管间距、埋管深度等因素对热流密度的影响。结果表明:基于地板辐射方式利用地埋管换热器地下余冷能够改善夏季室内舒适度提升系统能效比同时在一定程度上减弱地下冷热负荷的不平衡程度。蓄冷量及供冷能力大小与蓄冷体体积、比热容、供冷初始温度、供冷结束温度及冷耗散有关。地埋管区域的换热性能受地下水渗流、热扩散率以及地热换热器的构造形式影响较大。
Keywords:
radiant cooling ground-coupled heat pump cold energy application
文献标志码:
A
摘要:
辐射供冷;地源热泵;余冷利用
Abstract:
The floor radiant cooling system is numerically investigated on the basis of the proposed unsteady-state heat transfer model in this study. According to the simulation results, the effects of the various parameters on the heat transfer rates are discussed, such as the water supply temperature, the design temperature of indoor air, the pipe space and the burial depth. The simulation results demonstrate that the floor radiant cooling system which utilizes the underground cold storage of the ground heat exchanger (GHE) can improve the indoor comfort and increase the system energy performance. Furthermore, it can effectively alleviate the imbalanced cooling and heating loads of the GHE for a ground-coupled heat pump system.